- BỘ PHÁT WIFI
- THIẾT BỊ CHIA MẠNG SWITCH
- BỘ ĐỊNH TUYẾN ROUTER
- THIẾT BỊ TƯỜNG LỬA FIREWALL
- MÁY CHỦ (SERVER)
- BỘ LƯU TRỮ - Storage
- BỘ LƯU ĐIỆN UPS
- BẢN TIN CÔNG NGHỆ
- Quay về
- Xem tất cả "BỘ PHÁT WIFI"
- -Cisco Wi-Fi
- -Ruckus Wi-Fi
- -Ruijie Wi-Fi
- -Grandstream Wi-Fi
- -Aruba Wi-Fi
- -Alcatel Wi-Fi
- -Unifi Wi-Fi
- -Huawei Wi-Fi
- -H3C Wi-Fi
- -Juniper Wi-Fi
- Quay về
- Xem tất cả "THIẾT BỊ CHIA MẠNG SWITCH"
- -Cisco Switches
- -Fortinet Switches
- -H3C Switches
- -HPE Aruba Switches
- -Alcatel-Lucent Switches
- -Ruijie Switches
- -Mikrotik Switches
- -Juniper Switch
- Quay về
- Xem tất cả "BỘ ĐỊNH TUYẾN ROUTER"
- -Router Mikrotik
- -Router H3C series
- -UBNT Router
- -Router Cisco
- -Router Linksys
- -Router Peplink Balance
Gợi ý cho bạn:
RG-S7810C-X 10 RU Modular Campus Core Switch
Mã sản phẩm: RG-S7810C-X Tình trạng: Còn hàng Thương hiệu: Ruijie- Thiết kế khung máy nhỏ gọn với chiều cao 10 RU, cải thiện khả năng sử dụng không gian tủ
- Kiến trúc Clos trực giao, cung cấp thiết kế không có mặt phẳng sau và đảm bảo chuyển tiếp gói tin không bị chặn và truyền tốc độ cao mà không bị mất gói tin
- VSU, cung cấp khả năng kết nối mạng linh hoạt và hiệu suất cao
- Bảo vệ đa cấp phần cứng, mang lại độ tin cậy cấp nhà mạng
- Phần mềm quản lý SOE INC, cho phép O&M đơn giản và hiệu quả
Sản Phẩm Chính Hãng 100% Đầy Đủ CO/CQ
Giá Cạnh Tranh Rẻ Nhất Thị Trường
Giao Hàng Trên Toàn Quốc
Hỗ Trợ Kỹ Thuật Chuyên Nghiệp, Nhiệt Tình
Ưu Đãi Lớn Cho Đại Lý Và Dự Án
Chăm Sóc Khách Hàng Trước, Trong và Sau Khi Mua Hàng Tận Tâm.
THƯỜNG ĐƯỢC MUA CÙNG
Mô tả sản phẩm
Tổng quan về dòng RG-S7800C và RG-S7800C
Bộ chuyển mạch dòng RG-S7800C và RG-S7800C-X, bộ chuyển mạch lõi đa dịch vụ do Ruijie Networks phát hành dành cho mạng hội tụ thế hệ tiếp theo, tích hợp các tính năng của mạng trường học và trung tâm dữ liệu.
Sử dụng hệ điều hành mô-đun (OS), RG-S7800C và RG-S7800C-X hỗ trợ IPv4, IPv6 và các dịch vụ mạng khác, đáp ứng các yêu cầu ứng dụng của Ethernet trong tương lai. Ngoài ra, nó còn hỗ trợ Bộ chuyển mạch ảo (VSU) giúp đơn giản hóa kiến trúc mạng của khách hàng và cải thiện hiệu quả O&M.
Các bộ chuyển mạch dòng RG-S7800C và RG-S7800C-X có thể được triển khai trên MAN, mạng trường học và trung tâm dữ liệu dựa trên yêu cầu dịch vụ. Chúng đặt nền tảng cho các mạng hiệu suất cao hỗ trợ quản lý vòng đời dịch vụ IoT, ứng dụng di động và ứng dụng đám mây

Đặc điểm nổi bật
- Sử dụng kiến trúc đa mặt phẳng đa cấp Clos tiên tiến để tách mặt phẳng điều khiển khỏi mặt phẳng chuyển tiếp. Điều này đảm bảo chuyển mạch không bị chặn ở tốc độ đường truyền giữa tất cả các giao diện và mang lại khả năng hỗ trợ dịch vụ và nâng cấp băng thông liên tục.
- Cung cấp hệ thống tiết kiệm năng lượng và hệ thống cung cấp điện hiệu quả cao, hỗ trợ quản lý năng lượng động và được trang bị mô-đun quạt thông minh để điều chỉnh tốc độ đa cấp, giảm đáng kể mức tiêu thụ năng lượng.
- Sử dụng hệ điều hành mô-đun RGOS để cung cấp nhiều mục hơn, xử lý phần cứng nhanh hơn và trải nghiệm vận hành tốt hơn.
- Cung cấp hệ điều hành mô-đun RGOS mở và có thể lập trình.
- Các chức năng cơ bản được tích hợp vào phiên bản chính và các chức năng tùy chỉnh được phát hành ở chế độ ứng dụng, đảm bảo tính ổn định của các chức năng cơ bản.
- Hỗ trợ nền tảng x86, hỗ trợ bộ chứa, cho phép cài đặt ứng dụng quản lý của bên thứ ba và giúp dễ dàng tùy chỉnh các chức năng. Khắc phục các lỗi liên quan đến quy trình trực tuyến trong vài giây mà không làm gián đoạn hoạt động của mạng
- Hỗ trợ Python cho phép các ứng dụng trên nhiều nền tảng.
- Hỗ trợ truy cập tốc độ cao vào các giao diện hướng bắc, với hiệu suất lên tới hàng nghìn thao tác. Nó có thể liên kết với bộ điều khiển để nâng cấp giao diện người-máy lên giao diện máy-máy. Nâng cấp và mở rộng các chức năng trực tuyến để đảm bảo các dịch vụ không ngừng nghỉ.
- Phù hợp với mạng di động hoặc IoT của một khuôn viên rộng lớn nơi hàng nghìn thiết bị đầu cuối được triển khai; tự động cô lập nhiều mạng dịch vụ, độc lập với giao diện và vị trí. Điều này giúp đơn giản hóa việc triển khai. Kết nối và cách ly an toàn các thiết bị đầu cuối và người dùng IoT.
- Đối phó với hoạt động không mất dữ liệu của các dịch vụ trên mạng di động hoặc Internet với băng thông cao, đạt được tính liên tục của dịch vụ.
- Được sử dụng làm thiết bị cốt lõi của mạng trường học hoặc dịch vụ IoT, với hiệu suất mạnh mẽ và độ tin cậy cao để kết nối thông minh với thiết bị đầu cuối IoT và thiết bị đầu cuối di động
Ruijie RG-S7810C-X – Switch Core Modular Hiệu Suất Cao 10 RU
Ruijie RG-S7810C-X là switch core modular thế hệ mới, lý tưởng cho các mạng doanh nghiệp lớn, trung tâm dữ liệu và hệ thống mạng khuôn viên. Với thiết kế khung gầm nhỏ gọn 10 RU, thiết bị hỗ trợ 8 khe cắm line card, cho phép triển khai đa dạng với các module quang mật độ cao, đáp ứng linh hoạt nhu cầu mở rộng mạng. Công nghệ Orthogonal Clos không sử dụng backplane giúp truyền tải tốc độ cao, giảm thiểu độ trễ và tối ưu hóa hiệu suất.
Thiết bị tích hợp công nghệ ảo hóa VSU, hợp nhất nhiều switch vật lý thành một đơn vị logic duy nhất, giúp quản lý dễ dàng và đảm bảo chuyển đổi liên kết nhanh (50-200ms), duy trì hoạt động liên tục cho các dịch vụ quan trọng. Hệ thống dự phòng phần cứng bao gồm module điều khiển, nguồn điện và quạt có thể thay thế nóng, giúp tăng độ bền và đảm bảo độ tin cậy cấp nhà mạng.
Với dung lượng chuyển mạch lên đến 385 Tbps và tốc độ chuyển tiếp gói tin đạt 155.520 Mpps, RG-S7810C-X đáp ứng tốt nhu cầu băng thông lớn, phù hợp với các hệ thống cần khả năng xử lý dữ liệu nhanh chóng. Ngoài ra, thiết bị được tích hợp nền tảng quản lý thông minh SOE INC, giúp tự động nhận diện, cấu hình thiết bị và hỗ trợ thay thế nhanh mà không cần cấu hình lại, giúp giảm thời gian vận hành và bảo trì.

Với thiết kế tối ưu, hiệu suất mạnh mẽ và khả năng quản lý linh hoạt, RG-S7810C-X là giải pháp switch core modular lý tưởng cho các doanh nghiệp cần một hệ thống mạng đáng tin cậy, mở rộng linh hoạt và bảo mật cao.
Thông số kĩ thuật
Port specifications | RG-S7805C | RG-S7808C | RG-S7810C |
Module slot | 2 x supervisor module slots 3 x line card slots 2 x power module slots 1 x fan module slot | 2 x supervisor module slots 6 x line card slots 4 x power module slots 2 x fan module slots | 2 x supervisor module slots 8 x line card slots (slot 7 does not support the EB line card) 2 x switch fabric module slots 4 x power module slots 2 x fan module slots |
Supervisor module | M7805C-CM II | M7808C-CM II | M7810C-CM M7810C-CM-F |
Switch fabric module | / | M7808C-CM II (switch fabric module integrated with supervisor module) | M7810C-FE-D I (must be used with M7810C-CM) M7810C-FE-F I (must be used with M7810C-CM-F) M7810C-CM, M7810C-CM-F (switch fabric module integrated with supervisor module) |
line card | M7805C-CM II supports the following 9 modules: ● M7800C-32XS4QXS-DA ● M7800C-24GT24SFP4XS-EB ● M7800C-24SFP/12GT4XS-EB ● M7800C-48GT4XS-EB ● M7800C-48SFP4XS-EB ● M7800C-48GT-FA ● M7800C-48SFP-FA ● M7800C-48XS-FB ● M7800C-8CQ-FB *1 | M7808C-CM II supports the following 9 modules: ● M7800C-32XS4QXS-DA ● M7800C-24GT24SFP4XS-EB ● M7800C-24SFP/12GT4XS-EB ● M7800C-48GT4XS-EB ● M7800C-48SFP4XS-EB ● M7800C-48GT-FA ● M7800C-48SFP-FA ● M7800C-48XS-FB ● M7800C-8CQ-FB *1 | M7810C-CM supports the following 5 modules: ● M7800C-32XS4QXS-DA ● M7800C-24GT24SFP4XS-EB ● M7800C-24SFP/12GT4XS-EB ● M7800C-48GT4XS-EB ● M7800C-48SFP4XS-EB M7810C-CM-F supports the following 4 modules: ● M7800C-48GT-FA ● M7800C-48SFP-FA ● M7800C-48XS-FB ● M7800C-8CQ-FB *1 |
Power module | RG-PA300I-F RG-PA460I-F RG-PA1000I-F | RG-PA600I-F RG-PA1600I-F | RG-PA600I RG-PA1600I |
Fan module | M05C-FAN (pre-installed 1) | M08-FAN (pre-installed 2) | M10C-FAN (pre-installed 2) |
Module management port | M7805C-CM II: ● 1 x RJ45 console port ● 1 x RJ45 MGMT port | M7808C-CM II: ● 1 x RJ45 console port ● 1 x RJ45 MGMT port | M7810C-CM: ● 1 x RJ45 console port ● 1 x RJ45 MGMT port M7810C-CM-F: ● 1 x RJ45 console port *2 ● 1 x mini USB console port *2 ● 1 x RJ45 MGMT port |
USB | M7805C-CM II: 1 x USB 2.0 port (no capacity limit, 2G/4G/8G/16G/32G capacity tested) | M7808C-CM II: 2 x USB 2.0 ports (no capacity limit, 2G/4G/8G/16G/32G capacity tested) | M7810C-CM: 1 x USB 2.0 port M7810C-CM-F: 1 x USB 2.0 port (no capacity limit, 2G/4G/8G/16G/32G capacity tested) |
*1 Note: FA/FB series cannot be used with EB series or DA series.
*2 Note: Only one console port is allowed to be used at the same time. The mini USB console port has a higher priority.
System specifications | RG-S7805C | RG-S7808C | RG-S7810C |
System packet forwarding rate *3 | 4500 Mpps | 9000 Mpps | 12000 Mpps |
System switching capacity *4 | 6000 Gbps | 12000 Gbps | 16000 Gbps |
CPU | Supervisor module: ● M7805C-CM II: quad-core CPU, each core with the clock speed of 1.0 GHz Line card ● EB card: quad-core CPU, each core with the clock speed of 1.0 GHz ● DA/FA/FB card: quad-core CPU, each core with the clock speed of 1.5 GHz | Supervisor module: ● M7808C-CM II: quad-core CPU, each core with the clock speed of 1.5 GHz Line card ● EB card: quad-core CPU, each core with the clock speed of 1.0 GHz ● DA/FA/FB card: quad-core CPU, each core with the clock speed of 1.5 GHz | Supervisor module: ● M7810C-CM, M7810C-CM-F: quad-core CPU, each core with the clock speed of 1.5 GHz Line card ● EB card: quad-core CPU, each core with the clock speed of 1.0 GHz ● DA/FA/FB card: quad-core CPU, each core with the clock speed of 1.5 GHz Switch fabric module ● M7810C-FE-D I, M7810C-FE-F I: quad-core CPU, each core with the clock speed of 1.5 GHz |
Real-time clock (RTC) | M7805C-CM II: supported | M7808C-CM II: supported | M7810C-CM/M7810C-CM-F: supported |
BootROM | M7805C-CM II:8 MB EB card: 8 MB DA/FA/FB card: 16 MB | M7808C-CM II: 16 MB EB card: 8 MB DA/FA/FB card: 16 MB | M7810C-CM/M7810C-CM-F: 16 MB EB card: 8 MB DA/FA/FB card: 16 MB M7810C-FE-D I/M7810C-FE-F I: 16 MB |
Flash memory | M7805C-CM II: 1 GB EB card: 512 MB DA/FA/FB card: 8 GB | M7808C-CM II: 8 GB EB card: 512 MB DA/FA/FB card: 8 GB | M7810C-CM/M7810C-CM-F: 8 GB EB card: 512 MB DA/FA/FB card: 8 GB M7810C-FE-D I/M7810C-FE-F I: 8 GB |
Memory | M7805C-CM II: 4 GB DDR3 EB card: 1 GB DDR3 DA card: 1 GB DDR4 FA/FB card: 2 GB DDR4 | M7808C-CM II: 4 GB DDR4 EB card: 1 GB DDR3 DA card: 1 GB DDR4 FA/FB card: 2 GB DDR4 | M7810C-CM/M7810C-CM-F: 4 GB DDR4 EB card: 1 GB DDR3 DA card: 1 GB DDR4 FA/FB card: 2 GB DDR4 M7810C-FE-D I: 1 GB DDR4 M7810C-FE-F I: 2 GB DDR4 |
Switch buffer | EB: 4 MB FB: 32 MB FA: 8 MB DA: 16 MB | EB: 4 MB FB: 32 MB FA: 8 MB DA: 16 MB | EB: 4 MB FB: 32 MB FA: 8 MB DA: 16 MB |
*3 means the system's packet forwarding rate.
*4 means the system's switching capacity.
Power supply and consumption | RG-S7805C | RG-S7808C | RG-S7810C |
Power supply | 2 x pluggable power modules | 4 x pluggable power modules | 4 x pluggable power modules |
Power input | RG-PA300I-F (AC input): ● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz ● Maximum input current: 5 A RG-PA460I-F (AC input): ● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz ● Maximum input voltage: 90 V AC to 290 V AC; 45 Hz to 63 Hz ● Maximum input current: 6 A RG-PA1000I-F (AC input): ● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz ● Maximum input current: 10 A | RG-PA600I-F (AC input): ● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz ● Maximum input current: 10 A RG-PA1600I-F (AC input): ● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz ● Maximum input current: 16 A | RG-PA600I (AC input): ● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz ● Maximum input current: 8 A RG-PA1600I (AC input): ● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz ● Maximum input current: 16 A |
Maximum output power | RG-PA300I-F: 300 W RG-PA460I-F: 460 W RG-PA1000I-F: ● 100 V AC to 176 V AC: 800 W ● 176 V AC to 240 V AC: 1000 W | RG-PA600I-F: 600 W RG-PA1600I-F: ● 100 V AC to 176 V AC: 1200 W ● 176 V AC to 240 V AC: 1600 W | RG-PA600I: 600 W RG-PA1600I: ● 100 V AC to 176 V AC: 1200 W ● 176 V AC to 240 V AC: 1600 W |
Module power consumption | M05C-FAN: < 80 W M7805C-CM II: < 21 W | M08-FAN: < 88 W M7808C-CM II: < 50 W | M10C-FAN: < 216 W M7810C-CM: < 50 W M7810C-CM-F: < 110 W |
M7800C-32XS4QXS-DA: < 210 W M7800C-24GT24SFP4XS-EB: < 88 W M7800C-24SFP/12GT4XS-EB: < 85 W M7800C-48GT4XS-EB: < 70 W M7800C-48SFP4XS-EB: < 101 W M7800C-48GT-FA: < 75 W M7800C-48SFP-FA: < 95 W M7800C-48XS-FB: < 160 W M7800C-8CQ-FB: < 130 W | |||
Dimensions and Weight | RG-S7805C | RG-S7808C | RG-S7810C |
Unit dimensions (W x D x H) | 442 mm x 451 mm x 175 mm (17.40 in. x 17.76 in. x 6.89 in.) | 442.0 mm x 465.0 mm x 441.7 mm (17.40 in. x 18.31 in. x 17.39 in.) | 442.5 mm x 560.0 mm x 442.0 mm (17.42 in. x 22.05 in. x 17.40 in.) |
Shipping dimensions (W x D x H) | 750.0 mm x 600.0 mm x 455.0 mm (29.53 in. x 23.62 in. x 17.91 in.) | 710.0 mm x 590.0 mm x 735.0 mm (27.95 in. x 23.23 in. x 28.94 in.) | 845.0 mm x 685.0 mm x 770.0 mm (33.27 in. x 26.97 in. x 30.31 in.) |
Rack height | 4 RU | 10 RU | 10 RU |
Unit weight | 12.42 kg (27.38 lbs, empty chassis with 1 fan module) | 35.60 kg (78.48 lbs, empty chassis with 2 fan modules) | 43.60 kg (96.01 lbs, empty chassis with 2 fan modules) |
Shipping weight | 28.05 kg (61.84 lbs) | 43.93 kg (96.85 lbs) | 68.30 kg (150.58 lbs) |
Environment and reliability | RG-S7805C | RG-S7808C | RG-S7810C |
Temperature | Operating temperature: 0°C to 50°C (32°F to 122°F) Storage temperature: –40°C to +70°C (–40°F to +158°F) | ||
Humidity | Operating humidity: 10% to 90% RH (non-condensing) Storage humidity: 5% to 95% RH (non-condensing) | ||
Altitude | Operating altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.) Storage altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.) | ||
Mean time between failure (MTBF) | 216,000 hours (about 24 years) | 216,000 hours (about 24 years) | 342,000 hours (about 39 years) |
Fan | 1 x pluggable fan module (pre-installed) | 2 x pluggable fan modules (pre-installed) | 2 x pluggable fan modules (pre-installed) |
Heat dissipation | Supervisor module: right-to-left airflow Line card: right-to-rear airflow Power module: built-in fan modules drawing air outward, front-to-rear airflow | Supervisor module: right-to-rear airflow Line card: right-to-rear airflow Power module: front-to-rear airflow | Supervisor module: front-to-rear airflow Line card: side-to-rear airflow FE card: front-to-rear airflow |
Acoustic noise | 27°C (80.6°F): 70 dB Max Noise: 77 dB | 27°C (80.6°F): 70 dB Max Noise: 77 dB | 27°C (80.6°F): 70 dB Max Noise: 77 dB |
Supervisor module redundancy | 1+1 redundancy | 1+1 redundancy | 1+1 redundancy (same model) |
Power module redundancy | 1+1 redundancy (same model) | N+M redundancy (same model) | N+M redundancy (same model) |
Fan redundancy | Not supported | 1+1 redundancy | 1+1 redundancy |
Module hot swapping | Supported | Supported | Supported |
Power module hot swapping | Supported | Supported | Supported |
Fan module hot swapping | Supported | Supported | Supported |
Cable hot swapping | All ports on line cards support hot swapping of cables. The switch-mode power supply supports hot swapping of power cords. | ||
Power supply monitoring | Monitoring of the model, temperature, power, and voltage of the power supply module Power supply failure alarming Control of line card power-on based on the power supply status | ||
Fan monitoring | Fan speed adjustment: 256 levels Fan failure alarming | ||
Temperature monitoring | Over-temperature alarming | ||
ESD | ESD contact/air discharge: 6 kV/8 kV ESD susceptibility contact/air discharge: 8 kV/15 kV | ||
Surge protection | MGMT port: 4 kV Service port: 4 kV Power port: 6 kV | ||
Certifications and regulatory compliance | RG-S7805C | RG-S7808C | RG-S7810C |
Safety regulation | IEC 62368-1 | ||
EMC regulation | EN 300386, EN 55032 Class A, EN 55035, EN IEC 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 | ||
RoHS | European RoHS Directive 2011/65/EU & Amendment(EU) 2015/863 | ||
Hardware Specifications (with -X Series Supervisor Module)
Port specifications | RG-S7805C | RG-S7808C | RG-S7810C-X |
Module slot | 2 x supervisor module slots 3 x line card slots 2 x power module slots 1 x fan module slot | 2 x supervisor module slots 6 x line card slots 4 x power module slots 2 x fan module slots | 2 x supervisor module slots 8 x line card slots 4 x switch fabric module slots 4 x power module slots 2 x fan module slots |
Supervisor module | M7805C-CM-X | M7808C-CM-X | M7810C-CM-X |
Switch fabric module | / | M7808C-CM-X (switch fabric module integrated with supervisor module) | M7810C-FE-X I M7810C-FE-X II |
line card | M7800C-48GT4XS-XA M7800C-48SFP4XS-XA M7800C-24GT8SFP8XS-XA M7800C-32XS-XA M7800C-52XS-XB M7800C-12CQ-XB M7800C-48XT-P-XB | M7800C-48GT4XS-XA M7800C-48SFP4XS-XA M7800C-24GT8SFP8XS-XA M7800C-32XS-XA M7800C-52XS-XB M7800C-12CQ-XB M7800C-48XT-P-XB M7800C-8SFG-XB M7800C-8SFX-XB | M7800C-48GT4XS-XA M7800C-48SFP4XS-XA M7800C-24GT8SFP8XS-XA M7800C-32XS-XA M7800C-52XS-XB M7800C-12CQ-XB M7800C-48XT-P-XB M7800C-8SFG-XB M7800C-8SFX-XB |
Power module | RG-PA300I-F RG-PA460I-F RG-PA1000I-F | RG-PA600I-F RG-PA1600I-F | RG-PA600I RG-PA1600I RG-PD600I |
Fan module | M05C-FAN (pre-installed 1) | M08-FAN (pre-installed 2) | M10C-FAN (pre-installed 2) |
Module management port | M7805C-CM-X: ● 1 x RJ45 console port ● 1 x RJ45 MGMT port | M7808C-CM-X: ● 1 x RJ45 console port ● 1 x RJ45 MGMT port | M7810C-CM-X: ● 1 x RJ45 console port ● 1 x RJ45 MGMT port M7810C-FE-X I/II: ● 1 x RJ45 console port |
USB | M7805C-CM-X: 1 x USB 2.0 port (no capacity limit, 2G/4G/8G/16G/32G capacity tested) | M7808C-CM-X: 1 x USB 2.0 port (no capacity limit, 2G/4G/8G/16G/32G capacity tested) | M7810C-CM-X: 1 x USB 2.0 port (no capacity limit, 2G/4G/8G/16G/32G capacity tested) |
System specifications | RG-S7805C | RG-S7808C | RG-S7810C-X |
System packet forwarding rate *3 | 4500 Mpps | 9000 Mpps | 14300 Mpps |
System switching capacity *4 | 6000 Gbps | 12000 Gbps | 19200 Gbps |
CPU | Supervisor module: ● M7805C-CM-X: quad-core processor, each core 2.2 GHz Line card: ● XA/XB series line card: quad-core processor, each core 2.2 GHz | Supervisor module: ● M7808C-CM-X: quad-core processor, each core 2.2 GHz Line card: ● XA/XB series line card: quad-core processor, each core 2.2 GHz | Supervisor module: ● M7810C-CM-X: quad-core processor, each core 2.2 GHz Line card: ● XA/XB series line card: quad-core processor, each core 2.2 GHz |
Real-time clock (RTC) | M7805C-CM-X: supported | M7808C-CM-X: supported | M7810C-CM-X: supported |
BootROM | M7805C-CM-X: 16 MB XA/XB card: 16 MB | M7808C-CM-X: 16 MB XA/XB card: 16 MB | M7810C-CM-X: 16 MB M7810C-FE-X I/II: 16 MB XA/XB card: 16 MB |
Flash memory | M7805C-CM-X: 8 GB XA/XB card: 8 GB | M7808C-CM-X: 8 GB XA/XB card: 8 GB | M7810C-CM-X: 8 GB M7810C-FE-X I/II: 8 GB XA/XB card: 8 GB |
Memory | M7805C-CM-X: 4 GB DDR4 XA/XB card: 4 GB DDR4 | M7808C-CM-X: 4 GB DDR4 XA/XB card: 4 GB DDR4 | M7810C-CM-X: 4 GB DDR4 M7810C-FE-X I: 1 GB DDR4 M7810C-FE-X II: 4 GB DDR4 XA/XB card: 4 GB DDR4 |
Switch buffer | XA series line card (excluding M7800C-32XS-XA): 4 MB XB series line card: 35 MB M7800C-32XS-XA: 35 MB | XA series line card (excluding M7800C-32XS-XA): 4 MB XB series line card: 35 MB M7800C-32XS-XA: 35 MB | XA series line card (excluding M7800C-32XS-XA): 4 MB XB series line card: 35 MB M7800C-32XS-XA: 35 MB |
*3 means the system's packet forwarding rate.
*4 means the system's switching capacity.
Power supply and consumption | RG-S7805C | RG-S7808C | RG-S7810C-X |
Power supply | 2 x pluggable power modules | 4 x pluggable power modules | 4 x pluggable power modules |
Power input | RG-PA300I-F (AC input): ● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz ● Maximum input current: 5 A RG-PA460I-F (AC input): ● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz ● Maximum input voltage: 90 V AC to 290 V AC; 45 Hz to 63 Hz ● Maximum input current: 6 A RG-PA1000I-F (AC input): ● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz ● Maximum input current: 10 A | RG-PA600I-F (AC input): ● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz ● Maximum input current: 10 A RG-PA1600I-F (AC input): ● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz ● Maximum input current: 16 A | RG-PA600I (AC input): ● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz ● Maximum input current: 8 A RG-PA1600I (AC input): ● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz ● Maximum input current: 16 A RG-PD600I (DC input): ● Rated input voltage: –48 V DC ● Maximum input voltage: –40 V DC to –75 V DC ● Maximum input current: 20 A |
Maximum output power | RG-PA300I-F: 300 W RG-PA460I-F: 460 W RG-PA1000I-F: ● 100 V AC to 176 V AC: 800 W ● 176 V AC to 240 V AC: 1000 W | RG-PA600I-F: 600 W RG-PA1600I-F: ● 100 V AC to 176 V AC: 1200 W ● 176 V AC to 240 V AC: 1600 W | RG-PA600I: 600 W RG-PA1600I: ● 100 V AC to 176 V AC: 1200 W ● 176 V AC to 240 V AC: 1600 W RG-PD600I: 600 W |
Module power consumption | M05C-FAN: < 80 W M7805C-CM-X: < 40 W | M08-FAN: < 88 W M7808C-CM-X: < 62 W
M7800C-8SFG-XB: < 250 W M7800C-8SFX-XB: < 250 W | M10C-FAN: < 216 W M7810C-CM-X: < 60 W M7810C-FE-X I: < 50 W M7810C-FE-X II: < 160 W M7800C-8SFG-XB: < 250 W M7800C-8SFX-XB: < 250 W |
M7800C-48GT4XS-XA: < 85 W M7800C-48SFP4XS-XA: < 117 W M7800C-24GT8SFP8XS-XA: < 95 W M7800C-32XS-XA: < 149 W M7800C-52XS-XB: < 250 W M7800C-12CQ-XB: < 240 W M7800C-48XT-P-XB: < 300 W | |||
If the PoE function is used, you need to separately configure the PoE power chassis M78-PSE-X and the power module RG-PA1600I-PL for M7800C-48XT-P-XB.
Hardware Specifications | M78-PSE-X |
Fixed service port | 2 x PoE out ports |
Module slot | 2 x power module slots |
Power module | RG-PA1600I-PL |
Power supply | 2 x pluggable power modules |
Power input | RG-PA1600I-PL (AC input): ● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz ● Maximum input current: 16 A |
Maximum output power | RG-PA1600I-PL ● 100 V AC to 176 V AC: 1200 W ● 176 V AC to 240 V AC: 1600 W |
PoE output power | Each PoE out port provides up to 1,440 W of power |
Unit dimensions (W x D x H) | 400.0 mm x 420.0 mm x 44.7 mm (15.75 in. x 16.54 in. x 1.76 in.) |
Unit weight | 5.0 kg (11.02 lbs) |
Temperature | Operating temperature: 0°C to 50°C (32°F to 122°F) |
Humidity | Operating humidity: 10% to 90% RH (non-condensing) |
Mean time between failure (MTBF) | 4,289,000 hours (about 489 years) |
Power module redundancy | 1+1 redundancy (same model) |
Dimensions and Weight | RG-S7805C | RG-S7808C | RG-S7810C-X |
Unit dimensions (W x D x H) | 442 mm x 451 mm x 175 mm (17.40 in. x 17.76 in. x 6.89 in.) | 442.0 mm x 465.0 mm x 441.7 mm (17.40 in. x 18.31 in. x 17.39 in.) | 442.5 mm x 560.0 mm x 442.0 mm (17.42 in. x 22.05 in. x 17.40 in.) |
Shipping dimensions (W x D x H) | 750.0 mm x 600.0 mm x 455.0 mm (29.53 in. x 23.62 in. x 17.91 in.) | 710.0 mm x 590.0 mm x 735.0 mm (27.95 in. x 23.23 in. x 28.94 in.) | 845.0 mm x 685.0 mm x 770.0 mm (33.27 in. x 26.97 in. x 30.31 in.) |
Rack height | 4 RU | 10 RU | 10 RU |
Unit weight | 12.42 kg (27.38 lbs, empty chassis with 1 fan module) | 35.6 kg (78.48 lbs, empty chassis with 2 fan modules) | 43.55 kg (96.01 lbs, empty chassis with 2 fan modules) |
Shipping weight | 28.05 kg (61.84 lbs) | 43.93 kg (96.85 lbs) | 68.30 kg (150.58 lbs) |
Environment and reliability | RG-S7805C | RG-S7808C | RG-S7810C-X |
Temperature | Operating temperature: 0°C to 50°C (32°F to 122°F) Storage temperature: –40°C to +70°C (–40°F to +158°F) | ||
Humidity | Operating humidity: 10% to 90% RH (non-condensing) Storage humidity: 5% to 95% RH (non-condensing) | ||
Altitude | Operating altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.) Storage altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.) | ||
Mean time between failure (MTBF) | 216,000 hours (about 24 years) | 216,000 hours (about 24 years) | 342,000 hours (about 39 years) |
Fan | 1 x pluggable fan module (pre-installed) | 2 x pluggable fan modules (pre-installed) | 2 x pluggable fan modules (pre-installed) |
Heat dissipation | Supervisor module: right-to-left airflow Line card: right-to-rear airflow Power module: built-in fan modules drawing air outward, front-to-rear airflow | Supervisor module: right-to-rear airflow Line card: right-to-rear airflow Power module: front-to-rear airflow | Supervisor module: front-to-rear airflow Line card: side-to-rear airflow FE card: front-to-rear airflow |
Acoustic noise | 27°C (80.6°F): 70 dB Max Noise: 77 dB | 27°C (80.6°F): 70 dB Max Noise: 77 dB | 27°C (80.6°F): 70 dB Max Noise: 77 dB |
Supervisor module redundancy | 1+1 redundancy | 1+1 redundancy | 1+1 redundancy |
Power module redundancy | 1+1 redundancy (same model) | N+M redundancy (same model) | N+M redundancy (same model) |
Fan redundancy | Not supported | 1+1 redundancy | 1+1 redundancy |
Module hot swapping | Supported | Supported | Supported |
Power module hot swapping | Supported | Supported | Supported |
Fan module hot swapping | Supported | Supported | Supported |
Cable hot swapping | All ports on line cards support hot swapping of cables. The switch-mode power supply supports hot swapping of power cords. | ||
Power supply monitoring | Monitoring of the model, temperature, power, and voltage of the power supply module Power supply failure alarming Control of line card power-on based on the power status | ||
Fan monitoring | Fan speed adjustment: 256 levels Fan failure alarming | ||
Temperature monitoring | Over-temperature warning | ||
ESD | ESD contact/air discharge: 6 kV/8 kV ESD susceptibility contact/air discharge: 8 kV/15 kV | ||
Surge protection | MGMT port: 4 kV Service port: 4 kV Power port: 6 kV | ||
Certifications and regulatory compliance | RG-S7805C | RG-S7808C | RG-S7810C-X |
Safety regulation | IEC 62368-1 | ||
EMC regulation | EN 300386, EN 55032 Class A, EN 55035, EN IEC 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 | ||
RoHS | European RoHS Directive 2011/65/EU & Amendment(EU) 2015/863 | ||
Software Specifications (with -CM Series Supervisor Module)
Feature | RG-S7800C Series |
Ethernet switching | Jumbo frame (maximum length: 9,216 bytes) |
802.3az EEE | |
Maximum number of VLANs that can be created: 4,094 | |
Voice VLAN | |
Super-VLAN and private VLAN | |
MAC address-based, port-based, protocol-based, and IP subnet-based VLAN assignment | |
GVRP | |
Basic QinQ and selective QinQ | |
STP (IEEE 802.1.d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) | |
ERPS (G.8032) | |
LLDP/LLDP-MED | |
IP service | Static and dynamic ARP |
DHCP client | |
DHCP relay | |
DHCP server | |
DHCP snooping | |
DNS | |
DHCPv6 client, DHCPv6 relay, and DHCPv6 snooping | |
Neighbor Discovery (ND) and ND snooping | |
Manual tunnel, automatic tunnel, and ISATAP tunnel for IPv6 | |
GRE tunnel | |
IP routing | Static routing |
RIP and RIPng | |
OSPFv2 and OSPFv3 | |
GR | |
IPv4/IPv6 IS-IS | |
BGP4 and BGP4+ | |
EVPN | |
IPv4/IPv6 VRF | |
Policy-based routing (PBR) | |
IPv4 and IPv6 ECMP | |
Multicast | IGMP v1/v2/v3 |
IGMP snooping v1/v2/v3 | |
IGMP proxy | |
IGMP fast leave | |
PIM-DM, PIM-SM, and PIM-SSM | |
PIM-SSM for IPv4 and IPv6 | |
MSDP to achieve inter-domain multicast | |
MLDv1 and MLDv2 | |
Multicast static routing | |
MLD v1/v2 snooping | |
PIM-SMv6 | |
Multicast source IP address check Multicast source port check | |
MPLS | MPLS IPv6 |
MPLS L3VPN | |
MPLS 6VPE | |
MPLS MIB (RFC 1273, RFC 4265, and RFC 4382) | |
ACL and QoS | Standard IP ACLs (hardware ACLs based on IP addresses) |
Extended IP ACLs (hardware ACLs based on IP addresses or TCP/UDP port numbers) | |
Extended MAC ACLs (hardware ACLs based on source MAC addresses, destination MAC addresses, and optional Ethernet type) | |
Expert-level ACLs (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, and time range) | |
ACL80 and IPv6 ACL | |
Applying ACLs globally (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, and time range) | |
ACL redirection | |
Port traffic identification | |
Port-based rate limiting | |
802.1p | |
Traffic classification based on 802.1p priorities, DSCP priorities, and IP precedences | |
CAR | |
Congestion management: SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ | |
Congestion avoidance: tail drop, RED, and WRED | |
Eight queues on each port | |
Security | AAA |
RADIUS authorization and accounting | |
TACACS+ | |
Portal authentication, RADIUS, and TACACS+ login authentication | |
IEEE802.1X authentication, MAC address bypass (MAB) authentication, and interface-based and MAC address-based 802.1X authentication | |
Web authentication | |
Hypertext Transfer Protocol Secure (HTTPS) | |
SSHv1 and SSHv2 | |
Global IP-MAC binding | |
ICMP | |
Port security | |
IP source guard | |
DAI | |
SAVI | |
ARP spoofing prevention | |
CPU Protect Policy (CPP) and NFPP | |
Various attack defense functions, including NFPP and ARP anti-attack | |
uRPF Login authentication and password security Unknown multicast packets are not sent to the CPU, and unknown unicast packets can be suppressed. | |
Reliability | Rapid Ethernet Uplink Protection (REUP) |
Rapid Link Detection Protocol (RLDP), Layer 2 link connectivity detection, unidirectional link detection, and VLAN-based loop control | |
Data Link Detection Protocol (DLDP) | |
IPv4 VRRP v2/v3 and IPv6 VRRP | |
VRRP for the super-VLAN | |
BFD | |
RG-S7805C, RG-S7808C , RG-S7810C: 1+1 redundancy for supervisor modules | |
RG-S7805C: 1+1 redundancy for power supply RG-S7808C , RG-S7810C: N+M redundancy for power supply | |
RG-S7805C: fan redundancy is not supported RG-S7808C , RG-S7810C: 1+1 fan redundancy | |
Hot swapping of components | |
Hot patch and online installation of patches | |
GR for OSPF/IS-IS/BGP | |
BFD for VRRP/OSPF/BGP4/ISIS/ISISv6/static routing | |
Device virtualization | VSU |
NMS and maintenance | SPAN, RSPAN, and ERSPAN |
sFlow | |
NTP | |
SNTP | |
FTP, TFTP, and Xmodem | |
SNMP v1/v2c/v3 | |
RMON (1, 2, 3, 9) | |
NETCONF | |
CWMP | |
gRPC | |
OpenFlow Special 1.3 Flow table analysis defined by all protocols Transmission of specified packets to the controller Configuring the controller's IP address and port Notifying port status changes to the controller | |
Web-based NMS | |
Console/Telnet/SSH2.0 CLI configuration Fault alarms and auto-recovery System operation logging | |
VXLAN | Layer 2 and Layer 3 VXLAN gateways |
Software Specifications (with -X Series Supervisor Module)
Software Specifications | RG-S7800C-X Series |
Ethernet switching | Jumbo frame (maximum length: 9,216 bytes) |
802.3az EEE | |
Maximum number of VLANs that can be created: 4,094 | |
Voice VLAN | |
GVRP | |
IP subnet-based VLAN | |
MAC VLAN | |
Port-based VLAN | |
Private VLAN | |
protocol-based VLAN | |
Super-VLAN | |
Basic QinQ and selective QinQ | |
STP (IEEE 802.1.d) | |
RSTP (IEEE 802.1w) | |
MSTP (IEEE 802.1s) | |
ERPS (G.8032) | |
LLDP/LLDP-MED | |
Device Virtualization | VSU |
SDN | OpenFlow 1.3 NETCONF |
IP service | Static and dynamic ARP |
DHCP client | |
DHCP relay | |
DHCP server | |
DHCP snooping | |
DNS | |
DHCPv6 client | |
DHCPv6 relay | |
DHCPv6 snooping | |
Neighbor Discovery (ND) and ND snooping | |
FTP Server | |
FTP Client | |
NTP server | |
NTP Client | |
SNTP Client | |
TFTP Client | |
TFTP Server | |
IP routing | Static routing |
BGP4 | |
BGP4+ | |
IS-ISv4 | |
IS-ISv6 | |
OSPFv2 | |
OSPFv3 | |
RIP | |
RIPng | |
GR | |
Routing Policy | |
ECMP | |
IPv4/IPv6 VRF | |
Policy-based routing (PBR) | |
Multicast | IGMP v1/v2/v3 |
IGMP snooping v1/v2 | |
IGMP proxy | |
IGMP fast leave | |
PIM-DM | |
PIM-SM | |
PIM-SSM for IPv4 and IPv6 | |
MSDP to achieve inter-domain multicast | |
MLDv1 and MLDv2 | |
Multicast static routing | |
MLD v1/v2 snooping | |
PIM-SMv6 | |
Multicast source IP address check | |
Multicast source port check | |
MPLS | MPLS L3VPN |
MPLS 6VPE | |
MPLS IPv6 | |
MPLS forwarding | |
LDP | |
LSP | |
VXLAN | VXLAN Layer 2 bridge |
VXLAN Layer 3 gateway | |
EVPN VXLAN | |
ACL and QoS
| Standard IP ACL |
extended IP ACL | |
extended MAC ACL | |
Layer 2 and Layer 3 port ACL | |
VLAN ACL | |
Expert-level ACL | |
ACL 80 | |
IPv6 ACL | |
Applying ACLs globally | |
ACL COUNTER | |
ACL LOGGING | |
ACL REMARK | |
802.1P | |
SP | |
WRR | |
SP+WFR | |
other queue scheduling mechanisms | |
RED/WRED | |
Rate limiting based on the inbound or outbound interface | |
MPLS QOS | |
Reliability | RG-S7805C, RG-S7808C , RG-S7810C-X: 1+1 redundancy for supervisor modules |
RG-S7805C: 1+1 redundancy for power supply RG-S7808C , RG-S7810C-X: N+M redundancy for power supply | |
RG-S7805C: fan redundancy is not supported RG-S7808C , RG-S7810C-X: 1+1 fan redundancy | |
Hot swapping of all components | |
Hot patching function for online patch upgrade | |
GR | |
BFD | |
VRRP | |
VRRP+ | |
Faulty optical port isolation | |
Dual physical chips for boot systems | |
Security | NFPP |
CPP | |
DAI | |
port security | |
IP source guard | |
802.1X authentication | |
MAC address-based authentication | |
Portal authentication | |
RADIUS | |
TACACS+ login authentication | |
uRPF | |
SSHv2 | |
IPv6 SAVI | |
Login authentication and password security | |
providing encrypted security channels for user login | |
Unknown multicast packets are not sent to the CPU, and unknown unicast packets can be suppressed. | |
NMS and maintenance | Console/AUX Modem/Telnet/SSH2.0 CLI configuration |
File upload and download management using FTP, TFTP, and Xmodem | |
SNMP V1/V2c/V3 | |
RMON | |
CWMP | |
GRPC | |
Fault alarm and auto-recovery | |
System operation logging | |
sFlow | |
SPAN | |
RSPAN | |
ERSPAN | |
VLAN mirroring | |
Web-based NMS | |
Energy-Saving Design | IEEE 802.3az Energy Efficient Ethernet |